Free UK radiator sizing and heat-loss tool
Radiator BTU Calculator UK
Use this room BTU calculator, radiator size calculator and heat output calculator to work out what size radiator you need in Watts and BTU/h. It supports ΔT30, ΔT40, ΔT50, ΔT60, heat pumps and custom flow/return temperatures.
Radiator BTU Calculator
Enter your room details below. Use simple mode for a quick room-size estimate or advanced mode for a more detailed radiator heat-loss calculation.
How this radiator BTU calculator works
This radiator calculator starts with room volume, applies a base heat demand for the selected room type, then adjusts for glazing, external walls, insulation, floor, ceiling, exposure, target temperature and your chosen safety margin. The result is a practical radiator heat-output estimate in both Watts and BTU per hour.
BTU/h = Watts × 3.412
Why radiator Delta T matters
Radiator output changes with water temperature. A radiator running at ΔT30 gives out much less heat than the same model at ΔT50 or ΔT60. The calculator therefore converts your room requirement into the comparable ΔT50 catalogue rating to shop for.
A room-size and radiator-output calculator
- Simple and advanced calculation modes
- ΔT30, ΔT40, ΔT50, ΔT60 and custom Delta T support
- Transparent breakdown instead of a black-box answer
- Shows Watts, BTU/h and the radiator output to shop for
Typical base heat demand by room type
These are the starting values used before heat-loss adjustments are applied.
Radiator sizing guide
What size radiator do I need?
The correct radiator size is the output needed to replace the heat your room loses on a cold day. Physical width and height matter for fitting the radiator, but heat output is the figure that determines whether it can warm the room. Use the calculator first, then choose a radiator whose stated output meets or slightly exceeds the result at the correct Delta T.
Measure the room
Enter the internal length, width and ceiling height. The calculator uses these measurements to find floor area and room volume.
Add heat-loss details
Select glazing, external walls and insulation. Advanced mode also considers the roof, floor, exposure, orientation and external doors.
Select the heating system
Choose ΔT30 for many heat-pump systems, ΔT40 for lower-temperature boilers, ΔT50 for catalogue comparison, or enter custom temperatures.
Compare radiator outputs
Match the calculator result to the manufacturer's stated Watts or BTU/h. Check that both figures use the same Delta T rating.
Heat output conversion
Radiator Watts to BTU conversion chart
Radiator output may be shown in Watts, kilowatts or BTU/h. They describe the same heat output in different units. Use BTU/h = Watts × 3.412, Watts = BTU/h × 0.293, and kW = Watts ÷ 1,000.
| Watts | Kilowatts | BTU/h | Typical comparison |
|---|---|---|---|
| 300 W | 0.30 kW | 1,024 BTU/h | Small cloakroom or supplementary heat |
| 500 W | 0.50 kW | 1,706 BTU/h | Small bedroom or hallway |
| 750 W | 0.75 kW | 2,559 BTU/h | Small-to-medium room |
| 1,000 W | 1.00 kW | 3,412 BTU/h | Common room-heating target |
| 1,500 W | 1.50 kW | 5,118 BTU/h | Medium or higher-loss room |
| 2,000 W | 2.00 kW | 6,824 BTU/h | Larger room or split radiators |
| 2,500 W | 2.50 kW | 8,530 BTU/h | Large or exposed space |
| 3,000 W | 3.00 kW | 10,236 BTU/h | Large room with substantial heat loss |
The examples in the final column are only broad comparisons. Room construction and system temperature can change the required output substantially.
Radiator output chart
Delta T30, T40, T50 and T60 radiator output
Delta T is the difference between the radiator's mean water temperature and the room temperature. A product rated at ΔT50 will not deliver its full catalogue output when run on a lower-temperature system. The approximate factors below use a common radiator exponent of 1.3; always use the manufacturer's own correction table where one is supplied.
| Operating Delta T | Approx. output versus ΔT50 | ΔT50 catalogue rating needed for 1,000 W room demand | Common use |
|---|---|---|---|
| ΔT30 | 51% | About 1,943 W | Heat pump / low-temperature system |
| ΔT40 | 75% | About 1,337 W | Lower-flow condensing boiler |
| ΔT50 | 100% | 1,000 W | Common UK catalogue comparison |
| ΔT60 | 127% | About 789 W | Older higher-temperature system |
Low-temperature heating
Heat pump radiator size calculator guidance
Heat pumps usually work best with lower water temperatures. That reduces the output of every radiator, so a heat-pump radiator often needs more panel area, more convector fins or multiple emitters. Select ΔT30—or enter the proposed flow and return temperatures—to see the larger ΔT50 catalogue rating needed to deliver the room's heat demand.
- Do not compare a ΔT30 requirement directly with a product advertised only at ΔT50.
- Oversizing emitters can help a system operate at a lower flow temperature.
- Confirm design temperatures and room heat losses with the heat-pump designer or installer.
Existing radiator output
How many BTUs is my radiator?
You cannot reliably calculate an existing radiator's BTU output from height and width alone. Output also depends on its type, depth, number of panels, number of convector fins, water temperature and manufacturer. Look for a model label or identify whether it is Type 10, 11, 21, 22 or 33, then check the matching manufacturer output chart at the correct Delta T.
When replacing a radiator, measure width, height, depth and pipe centres, but compare the old and new radiator by heat output—not only physical size.
Room radiator calculator guidance
Calculate radiator size for different rooms
The same room dimensions can need different radiator outputs because target temperatures, glazing and exposure vary. These room guides explain which calculator settings deserve the most attention.
Living room radiator size
Use the full room volume and include patio doors, large windows and every external wall. For open-plan spaces, measure the whole connected heated area.
Bedroom radiator size
Bedrooms often use a lower target temperature than bathrooms or living rooms, but north-facing walls, bay windows and rooms over garages can increase heat loss.
Bathroom BTU calculator
Bathrooms normally need a warmer target temperature. If using a towel rail as the only heat source, check its output when towels cover part of the surface.
Use the towel rail size calculatorKitchen radiator size
Do not permanently deduct heat from cooking appliances. Base the calculation on the room itself and make sure the chosen radiator fits around cabinets and doors.
Conservatory BTU calculator
Conservatories commonly have a high glazed area and several external surfaces. Enter the real window area and use advanced mode for a more cautious heat-loss estimate.
Loft room or home office
Roof insulation, sloping ceilings and exposed walls matter. Use the average ceiling height where the roof slopes and select the closest roof condition in advanced mode.
Splitting heat output
How many radiators do I need?
One correctly sized radiator can meet the total room demand, but two or more radiators may distribute warmth more evenly in a long room, large open-plan space or room with several cold external walls. Use the “split across radiators” control to divide the required output. The combined stated output must still meet the total.
For example, a 2,000 W requirement could be met by one 2,000 W radiator or two radiators rated around 1,000 W each at the same Delta T.
Product selection
Radiator dimensions versus radiator output
A larger radiator usually produces more heat, but width alone does not determine output. A compact double-panel double-convector radiator can outperform a wider single-panel model. Choose the required output first, then filter by available wall width, height, depth, style and pipe position.
- Compare products at the same Delta T.
- Check whether the stated figure is Watts or BTU/h.
- Allow suitable clearance and follow the installation instructions.
Method and assumptions
How the radiator heat-loss estimate is calculated
This calculator is designed to give a transparent estimate rather than a hidden single-number answer. It calculates room volume, applies a room-specific starting demand, adjusts for the selected heat-loss conditions, adds the chosen margin, and then converts the room demand to the radiator catalogue output needed at your operating Delta T.
| Calculation stage | How it is used |
|---|---|
| Room volume | Length × width × height, with feet converted to metres where imperial units are selected. |
| Base room demand | A starting W/m³ rate is selected for the room type before heat-loss adjustments. |
| Glazing and external surfaces | Window type, glazed area and number of external walls adjust the base demand. |
| Advanced heat-loss factors | Property age, wall type, roof/room above, floor/room below, exposure, orientation and doors can be included. |
| Comfort and uncertainty | Target room temperature and the selected safety margin adjust the final room requirement. |
| Delta T conversion | The operating Delta T is used to calculate the equivalent ΔT50 product rating to look for. |
Radiator BTU Calculator FAQs
Seven practical answers covering the questions most people need before choosing a radiator.
What size radiator do I need?
The right radiator size is based on the room's required heat output, not its dimensions alone. Measure the room, account for insulation, glazing and external walls, then compare the calculator's Watts or BTU/h result with radiator outputs stated at the same Delta T.
How do I calculate BTU for a room?
Measure the room length, width and height to calculate its volume, then adjust the starting heat demand for glazing, insulation, external walls and target temperature. The calculator completes these steps and converts the result from Watts to BTU/h.
How do I calculate the BTU output of an existing radiator?
Identify the radiator model or panel and convector type, measure its height and width, and check the manufacturer's output chart at the correct Delta T. Dimensions alone cannot determine an existing radiator's output accurately.
Should I compare radiators at ΔT30, ΔT40, ΔT50 or ΔT60?
Compare radiator outputs at the Delta T that reflects your heating system. ΔT50 is a common UK catalogue comparison point, while heat pumps and lower-temperature systems may operate closer to ΔT30 or ΔT40 and therefore need more radiator surface area.
Do heat pumps need bigger radiators?
Often, yes. Heat pumps usually run at lower water temperatures, so the same radiator gives out less heat. A larger radiator, an additional radiator or another low-temperature heat emitter may be required to meet the room heat loss.
Can I split the required output across two radiators?
Yes. Add the outputs of both radiators at the same Delta T. Their combined output should meet or slightly exceed the total room requirement, and using two radiators can distribute warmth more evenly in a long or open-plan room.
How do I choose the right towel rail size for a bathroom?
Use the bathroom setting and a warmer target temperature, then account for glazing, external walls and ventilation. A towel rail used as the main heat source must provide enough room heat even when towels cover part of its surface. Use our towel rail size calculator for a more specific estimate.