Radiator Delta T Converter Calculator

Free UK radiator output tool

Radiator Delta T Converter Calculator for ΔT30, ΔT50 & ΔT60

Convert radiator output between ΔT30, ΔT40, ΔT50 and ΔT60. Check radiator Watts, BTU/h and low-temperature heating output.

Convert Radiator Output Between Delta T Ratings

Use simple mode for common radiator listings. Use advanced mode for custom temperatures, heat pumps and buying checks.

In plain English: A radiator gives less heat when the water inside it is cooler. This tool helps you compare radiator ratings fairly.
Enter the heat output shown on the radiator product page.
Radiators may be listed in Watts, BTU/h, or both.
This is the Delta T used for the product’s published output.
Choose the temperature rating you want to compare against.

What Is Delta T?

Delta T is the gap between the average radiator water temperature and the room temperature. The smaller the gap, the less heat the radiator gives out.

ΔT = average radiator water temperature − room temperature

Why ΔT50 and ΔT30 Are Different

A radiator rated at ΔT50 will not give the same heat on a cooler ΔT30 system. This is why heat pump and low-temperature systems often need larger radiators.

Lower Delta T = lower radiator output

When to Use Advanced Mode

Use advanced mode if you know your flow and return temperatures, are sizing for a heat pump, or want to check what radiator rating to buy.

Common Radiator Delta T Ratings

These are common comparison points used when looking at radiator output.

Delta T Plain-English meaning
ΔT60 Older high-temperature systems. Output looks higher than ΔT50.
ΔT50 Common UK radiator comparison rating.
ΔT40 Lower-temperature boiler systems.
ΔT30 Low-temperature heating and some heat pump comparisons.
ΔT20 / ΔT25 Very low-temperature systems. Radiators may need to be much larger.

Radiator Delta T Converter FAQs

What does ΔT50 mean on a radiator?

ΔT50 means the radiator output is based on the average radiator water temperature being 50°C warmer than the room. It is a common UK comparison rating.

How do I convert radiator output from ΔT50 to ΔT30?

Enter the radiator output, select ΔT50 as the published rating, then choose ΔT30 as the target rating. The calculator estimates the lower output at ΔT30.

Why is radiator output lower at ΔT30?

At ΔT30, the radiator water is closer to the room temperature, so less heat passes from the radiator into the room.

Should I use simple or advanced mode?

Use simple mode for quick ΔT30, ΔT40, ΔT50 and ΔT60 conversions. Use advanced mode for custom temperatures, heat pumps and buying checks.

Can I use this for heat pumps?

Yes. For best results, use advanced mode and enter the flow temperature, return temperature and room temperature.

Is this exact?

No. This is an estimate. For final radiator sizing, check the manufacturer’s technical data where available.